PHILIPS TRANSDUCERS


S8-3t




Sector array multiplane microTEE

  • Micro transesophageal sector array
  • 8 to 3 MHz extended operating frequency range
  • Physical dimensions
    • Tip: 7.5 x 5.5 x 18.5 mm (width, height, length)
    • Shaft diameter: 5.2 mm
    • Adult length gastroscope: 85 cm


  • Manually rotatable multiplane array from 0 to 180 degrees
  • Manual control of anterior and posterior flexion
  • 2D, steerable PW Doppler, CW Doppler, color Doppler, advanced XRES, M-mode, and harmonic imaging
  • Pediatric, including infants, and adult TEE application

D2tcd


Pulsed Wave Transducer (Pedoff)

  • Dedicated 2 MHz pulsed wave Doppler
  • Transcranial Doppler applications
  • Peripheral vascular applications

C5-1


Broadband Curved Array Transducer with PureWave Crystal Technology

  • 5 to 1 MHz extended operating frequency range
  • Steerable pulsed, High-PRF and color Doppler; and Color Power
  • Angio, SonoCT, advanced XRES, and multi-variate harmonic imaging
  • General purpose abdominal, obstetrical,  gynecological, and interventional applications
  • Discreet TSI for deep abdominal, obstetrical, and gynecological penetration enables:
    • Tissue aberration correction
    • Coded beamforming with chirp transmit and coded harmonics
  • Supports biopsy guide capabilities

* Not all features available on all systems

C10-3V


C10-3v broadband curved array with PureWave crystal technology
  • 10 to 3 MHz extended operating frequency range
  • End-fire sector, 11.5 mm radius of curvature, 130° field of view
  • Steerable pulsed wave and color Doppler, Color Power Angio, advanced XRES, and harmonic imaging
  • Endovaginal applications
  • Supports biopsy guide capabilities

C9-5ec


Broadband Curved Array Transducer
  • 9 to 5 MHz extended frequency range
  • End-fire sector, 8 mm radius of curvature, 150ยบ field of view
  • Steerable pulsed wave and color Doppler, Color Power Angio, Freehand 3D, Panoramic, SonoCT, XRES, and harmonic imaging*
  • Endocavitary applications including vaginal and rectal
  • Contrast applications
  • Supports biopsy guide capabilities

* All features not available on all systems


C8-4v


Broadband Curved Array Transducer

  • 8 to 4 MHz extended operating frequency range
  • End-fire sector, 11 mm radius of curvature
  • 2D, steerable pulsed wave and color Doppler, M-mode, Color Power Angio, SonoCT, XRES, Panoramic, Freehand 3D and harmonic imaging*
  • Endovaginal applications
  • Contrast applications
  • Supports biopsy guide capabilities

*Not all features are available on all systems.



VL13-5


Broadband Linear Array
  • 13 to 5 MHz extended operating frequency range
  • Fine pitch, 192 element, high resolution linear array
  • Steerable pulsed wave and color Doppler, Color Power Angio, SonoCT, XRES, and harmonic imaging
  • Supports high resolution 2D imaging
  • Supports high resolution, quantitative, single sweep 3D volume acquisition 
  • Supports 4D imaging
  • High resolution superficial applications including small parts, breast, and vascular imaging
  • Tissue aberration correction selection for advanced breast imaging TSI
  • Supports biopsy guide capabilities


3D9-3v


Broadband Curved Array Transducer

  • 9 to 3 MHz extended frequency range
  • 130° field-of-view
  • Supports high resolution 2D imaging
  • Supports high resolution, quantitative, single sweep 3D volume acquisition (hybrid and freehand).
  • Supports 4D imaging up to 22 volumes per second
  • Steerable pulsed wave and color Doppler, Color Power Angio, SonoCT, XRES, Panoramic, and harmonic imaging
  • Endovaginal applications
  • Supports biopsy guide capabilities


L17-5


Broadband Linear Array Transducer
  • 17 to 5 MHz extended frequency range
  • Ultra-fine pitch, high resolution linear array
  • 38 mm effective aperture length
  • Steerable pulsed wave and color Doppler, Color Power Angio, SonoCT, XRES, and harmonic imaging
  • Tissue aberration correction selection for advanced breast imaging TSI
  • High-resolution superficial applications including small parts, breast, superficial vascular, and musculoskeletal imaging
  • Elastography 
  • Supports biopsy guide capabilities


L12-5 50 mm


Broadband Linear Array Transducer

  • 12 to 5 MHz extended operating frequency range
  • Fine pitch, high resolution linear array
  • 50 mm effective aperture length
  • 10 degrees of trapezoidal imaging
  • Steerable pulsed wave, color Doppler, and Color Power Angio, Panoramic, SonoCT, XRES, and harmonic imaging*
  • High resolution superficial applications including vascular, small parts, breast, and musculoskeletal imaging
  • Contrast applications*
  • Elastography (iU22 system only)
  • Supports biopsy guide capabilities

* Not all features are available on all systems


S4-1


Broadband Sector Array Transducer
  • 4 to 1 MHz extended frequency range
  • Steerable pulsed wave Doppler, High-PRF Doppler, color Doppler, Color Power Angio, XRES, and harmonic imaging
  • Deep abdominal, obstetrical, gynecological, and interventional applications
  • Supports biopsy guide capabilities
  • Contrast applications

S3-1


Broadband Sector Array Transducer
  • 3 to 1 MHz extended frequency range
  • Steerable CW Doppler, PW Doppler, High PRF Doppler, Color Doppler, Color Power Angio, Tissue Doppler Imaging, Freehand 3D, XRES, and Harmonic Imaging
  • 90° field-of-view
  • Contrast applications
  • Adult cardiology applications, and transcranial Doppler
  • Explora connector with exceptional broadband response and new cable technology that is extremely flexible and lightweight

X6-1


xMATRIX Array Transducer with PureWave Crystal Technology
  • 6 to 1 MHz extended operating frequency range
  • Fully-sampled matrix phased array with 9,212 elements
  • Dynamic focusing over range in both lateral and elevation dimensions
  • Three line densities in 3D and 4D modes
  • General purpose abdominal, obstetrical, fetal echo, and gynecological applications
  • 2D modes include 2D, M-mode, color Doppler, Color Power Angio including directional CPA, pulsed Doppler, elevation compounding, biplane (Live xPlane) with color, 3D with color and CPA, 4D, triggered full volume with color, advanced XRES, and harmonic imaging
  • Auto-heart detection for triggered full volume fetal echo in grayscale and color
  • Supports biopsy guide capabilities

C6-3


Broadband Curved Array Transducer
  • 6 to 3 MHz extended operating frequency range
  • 50 mm radius of curvature
  • 2D, steerable pulsed Doppler, color Doppler, M-mode, Color Power Angio, SonoCT, harmonic imaging, Panoramic, XRES, and Freehand 3D
  • Abdominal, Ob/Gyn, pediatric, urology, emergency medicine, and regional anesthesia applications
  • Narrow footprint for improved intercostal access
  • Multi-angle biopsy kit available

L12-3


Broadband Linear Array Transducer

  • 12 to 3 MHz extended frequency range
  • 35 mm effective aperture length
  • 10° of trapezoidal imaging
  • Steerable pulsed wave and color Doppler and Color Power Angio, SonoCT, XRES, Panoramic and harmonic imaging
  • High-resolution superficial applications including small parts, breast, superficial vascular, and musculoskeletal imaging
  • Supports biopsy guide capabilities

C9-3v


Curved array with PureWave crystal technology
  • 9 to 3 MHz extended operating frequency range
  • High density curved array, 128 elements
  • End-fire sector, 11.5 mm radius of curvature, 130° field-of-view
  • Steerable pulsed wave, High PRF, and color Doppler, Color Power Angio, SonoCT, advanced XRES, and multi-variate harmonic imaging
  • Endovaginal applications
  • Supports disposable plastic biopsy guide (18 gauge) and stainless steel biopsy guide (16-18 gauge)


S5-2


Broadband Sector Array Transducer with PureWave Crystal Technology
  • 5 to 1 MHz extended operating frequency range
  • Phased array with 80 elements
  • Field of view: 90°
  • 2D, steerable PW Doppler and CW Doppler, High-PRF Doppler, color Doppler, Tissue Doppler, XRES, Freehand 3D, and harmonic imaging including LVO
  • Cardiac, abdominal, TCD and obstetrics, fetal echo, and emergency medicine applications