Monday 1 May 2017

ALOKA PROBES


     

 Pediatric Transducers


UST-5294-5


Multi Frequency Pediatric Phased Array Transducer

  •  The 5294-5 is our pediatric cardiac transducer. 
  •  This phased array transducer has multiple frequencies and superior color and Doppler capabilities. 
  •  This transducer combined with our Free Angular M-Mode technology revolutionizes the cardiac exam in the pediatric patient.

Main Specifications

  • Array type: Phased Array
  • Scan angle: 90°
  • Frequency range: 3-7.5 MHz
  • Sterilization: Sterrad*, ETO, 2% Gluteraldehyde, Cidex* OPA

 

UST-5298


Multi Frequency Pediatric Phased Array Transducer

  •  The 5298 is our pediatric cardiac transducer. 
  •  This phased array transducer has multiple frequencies and superior color and Doppler capabilities. 
  •  This transducer combined with our Free Angular M-Mode technology revolutionizes the cardiac exam in the pediatric patient.

Main Specifications

  • Array type: Phased Array
  • Scan angle: 90°
  • Frequency range: 3-7.5 MHz
  • Sterilization: Sterrad*, ETO, 2% Gluteraldehyde, Cidex* OPA

  

UST-9101-7.5


Multi Frequency Convex Abdominal Transducer

  •  The 9101-7.5 transducer is the best choice for pediatric abdominal imaging. 
  •  The high resolution obtained in this multi frequency transducer is ideal for your pediatric patients in need of quick and accurate diagnoses. 
  •  A choice of frequencies gives you the versatility you need, and allows you to obtain the highest quality images in the shortest time.

Main Specifications

  • Array type: Convex Array
  • Scan angle: 60°
  • Radius: 40 mm
  • Frequency range: 5-10 MHz
  • Puncture adapter: MP-2482
  • Sterilization: ETO, 2% Gluteraldehyde, Cidex* OPA

  

UST-9104-5


Multi Frequency Convex Neonatal Transducer The 9104-5 is our neonatal head multi frequency transducer with phenomenal color and Doppler sensitivity.
 

UST-9120-7.5


Multi Frequency Convex Neonatal Transducer

  •  The 9120-7.5 is our newest transducer developed specifically for our high end ProSound series of ultrasound systems. 
  •  This neonatal head transducer provides extraordinary color and Doppler sensitivity and multiple frequencies

Main Specifications

  • Array type: Convex Array
  • Scan angle: 70°
  • Radius: 20 mm
  • Frequency range: 3.75-10 MHz
  • Puncture adapter: MP-2458
  • Sterilization: Sterrad*, ETO, 2% Gluteraldehyde, Cidex* OPA

 


UST-987-7.5


Multi Frequency Convex Neonatal Transducer

  •  The 987-7.5 is the best choice for your most superficial neonatal head studies. 
  •  Multiple frequencies and a 65 degree scan angle and a 20 degree radius allows you to complete your exam quickly and accurately.

Main Specifications

  • Array type: Convex Array
  • Scan angle: 65°
  • Radius: 20 mm
  • Frequency range: 5-10 MHz
  • Puncture adapter: MP-2458

No comments:

Post a Comment

WHEN WE NEED TO REPAIR THE PROBE ???? Many of the probe damages are repairable at initial state. But in many cases the Practitio...