1. GE 6VT


Features
  •          4D Volume TEE transducer
  •          3.0-8.0 MHz frequency range
  •          Cardiac, LVO Contrast, Coronary TEE studies
  •          Active Matrix 4D volume phased array TEE
  •          14.4 x 12.7 mm tip footprint with 44.8mm length
  •          90-degree field of view
  •          20 cm depth
2. GE 6T


Features:
  • Transesophageal probe
  • Frequency 3.0-7.0 MHz
  • Compatible machines : GE Logiq and Vivid series

3. 6TV



Features:
  •  2.9 TO 6.7 MHz
  • 14 mm aperture
  • TEE Array
  • Compatible machines : GE Logiq 5/7/9 & Vivid 3/7

4. PHILIPS S7-3T



Features:
  • Transesophageal Phased Array
  • 48 elements
  • 7.0 to 3.0 MHz
  • 180 degrees Mechanical Rotation
  • Field of view: 90 degrees
  • Compatible machines : Philips iE33, HD15, HD11XE and HD11 ultrasound systems
  • The S7-3t probe can be utilized for pediatric and small adult TEE applications
  • It features steerable PW Doppler, as well as XRES.


5.PHILIPS X7-3T



Features:
  • 2D and 3D Matrix Array
  • 2,500 elements
  • 7.0 to 2.0 MHz
  • Compatible with Philips iE33 and CX50 ultrasound systems
  • The X7-2t probe can be utilized for TEE applications for patients less than 30 kg/66 lb
  • It features harmonic imaging, as well as dynamic elevational focusing

6. ACUSON V510B



Features:
  • Bi-plane transducer
  • 10 mm
  • Adult transesophageal probe
  • Frequency range of 3.5 to 5.0 MHz.
  • Compatible with the Acuson Aspen / 128XP10 series ultrasound systems

7. ACUSON TE-V7B



Features:
  • Biplane transducer
  • Frequency Range: 5.0 to 8.0 MHz
  • Transesophageal transducer
  • Frequency range of 5 to 8 MHz
  • Compatible with the Sequoia 512 GI series
  • The Acuson TE-V7B is used with pediatric, small adult TEE and for noenatal clinical applications

8. PHILIPS 21378A T6H




Features:
  • Philips 21378A T6H probe has frequency range of 2 to 7 MHz
  • It is an Omniplane III TEE ultrasound transducer
  • Compatible with a number of HP and Philips ultrasound systems. 
  • Used for transesophageal clinical applications.

9. SONOSITE TEEx




Features:
  • 360 degrees field view
  • 8-3 MHz operating frequency
  • 18 cm scan depth
  • TEE Transesophageal
  • Compatible with the SonoSite M-Turbo and SonoSite Edge ultrasound machines
  • Used for cardiac applications.




WHEN WE NEED TO REPAIR THE PROBE ???? Many of the probe damages are repairable at initial state. But in many cases the Practitio...